Bronze level automatically awarded US beta
This data has achieved Bronze level on 25 October 2015 which means this data makes a great start at the basics of publishing open data.
Goniophotometer for specular gloss calibrations - Glossmeter
Summary
- Type of release
- a one-off release of a set of related datasets
- Data Licence
- Not Applicable
- Content Licence
- Creative Commons CCZero
- Verification
- automatically awarded
- Release Date
- 15 October 2015
- Modified Date
- 15 October 2015
- Publishers
- Federal Laboratory Consortium
- Identifier
- goniophotometer-for-specular-gloss-calibrations-glossmeter
- Landing Page
- http://catalog.data.gov/dataset/goniophotometer-for-specular-gloss-calibrations-glossmeter
- Maintainers
- Maria Nadal maria.nadal@nist.gov
Community verification
Other people can verify whether the answers on this certificate are correct.
This certificate is automatically awarded.
Sign in to verify or report this certificate
Description
Specular gloss is the perception by an observer of the mirror-like appearance of a surface. The measurement of specular gloss consists of comparing the luminous reflectance from a test sample to that from a calibrated gloss standard, under the same experimental conditions. Therefore, gloss is a dimensionless and psychophysical quantity whose accurate determination depends on the characteristics of the measuring instrument and on the gloss standard. Several documentary standards describe the proper measurement conditions to determine specular gloss for specific surfaces. The International Organization for Standards ISO 2813 and the American Society for Testing Materials ASTM D523 describe the measurement procedure for specular gloss of nonmetallic samples, including the spectral and geometrical conditions of measurement. The spectral flux distribution of the illuminator is CIE standard illuminant C and the spectral responsivity of the receiver is the CIE spectral luminous efficiency function. There are also three standard geometries, corresponding to illumination angles of 20°, 60°, and 85°, each with specifications on the angular extent of the rays within the influx and efflux. The NIST reference goniophotometer was originally developed at NIST in the 1970's. In 1999, the goniophotometer was updated, automated, and characterized to ensure proper operation and to verify agreement with the ISO and ASTM standards for specular gloss of nonmetallic samples. This instrument is a monoplane gonio-instrument with a fixed illuminator and a rotating sample table and receiver arm. The illuminator supplies the influx onto the sample. It consists of a light source, a set of condenser lenses, a source aperture, a collimating lens, a depolarizer, a color filter, and an iris. The light source is a quartz-tungsten-halogen incandescent lamp rated at 100 W. A constant dc current of 6.3 A runs through the lamp from a computer-controlled power supply. This current was chosen so that the spectral flux distribution from the lamp approximates CIE standard illuminant A. A scrambler is used to provide unpolarized light, and a color filter BG-34, 2.7 mm thick, converts the spectral flux distribution to CIE standard illuminant C. The goniometer positions the sample and receiver for bi-directional luminous reflectance or transmittance measurements. It consists of two computer-controlled rotation stages. The sample stage has a diameter of 48 cm and the sample holder can accommodate rectangular samples with dimensions up to 10 cm high by 20 cm wide by 25 mm thick. The receiver is attached to a rotation stage whose axis of rotation is collinear with the rotation stage for the sample and collects and measures the efflux from the sample. It consists of an iris, a focusing lens, a receiver aperture, an averaging sphere, and a detector. The receiver aperture is located at the entrance port of the averaging sphere, and is the field stop of the receiver. The averaging sphere has a diameter of 30.5 cm and is packed with pressed polytetrafluoroethylene (PTFE). A photopic detector is located at the detector port of the averaging sphere and consists of a silicon photodiode and a filter that in combination approximates the spectral luminous efficiency function V λ. The detector is temperature controlled with a thermoelectric heater and has an integral current-to-voltage amplifier. The voltage output from the detector is measured by a 6 ½ digit voltmeter and sent to a computer. The accuracy of specular gloss measurements depends not only on the properties of the instrument but also to a considerable extent on the primary gloss standard. A new primary gloss standard using BaK50 barium crown glass has been developed at NIST. It possesses high chemical and mechanical durability and an index of refraction at the sodium D line of n D= 1.5677. Different calibration procedures are detailed, and the new standard is compared with other primary standards. The new gloss standard and the NIST reference goniophotometer provide an accurate calibration facility for specular gloss. The NIST Calibration Services Program offers Service ID Number 38090S, Special Test of Specular Gloss.
General Information
-
This data is described at
http://catalog.data.gov/dataset/goniophotometer-for-specular-gloss-calibrations-glossmeter Do you think this data is incorrect? Let us know
-
This data is published by
Federal Laboratory Consortium Do you think this data is incorrect? Let us know
Legal Information
-
The rights statement is at
http://catalog.data.gov/dataset/goniophotometer-for-specular-gloss-calibrations-glossmeter Do you think this data is incorrect? Let us know
-
Outside the US, this data is available under
Creative Commons CCZero Do you think this data is incorrect? Let us know
-
There are
yes, and the rights are all held by the same person or organisation Do you think this data is incorrect? Let us know
-
The content is available under
Creative Commons CCZero Do you think this data is incorrect? Let us know
-
The rights statement includes data about
its data licence Do you think this data is incorrect? Let us know
-
This data contains
no data about individuals Do you think this data is incorrect? Let us know
Practical Information
-
The data appears in this collection
http://catalog.data.gov/organization/federal-laboratory-consortium Do you think this data is incorrect? Let us know
-
The accuracy or relevance of this data will
go out of date but it is timestamped Do you think this data is incorrect? Let us know
-
The data is
backed up offsite Do you think this data is incorrect? Let us know
Social Information
-
The documentation includes machine-readable data for
title Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
description Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
identifier Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
landing page Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
publisher Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
release date Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
modification date Do you think this data is incorrect? Let us know
-
The documentation includes machine-readable data for
temporal coverage Do you think this data is incorrect? Let us know
-
Find out how to contact someone about this data at
http://catalog.data.gov/dataset/goniophotometer-for-specular-gloss-calibrations-glossmeter Do you think this data is incorrect? Let us know
-
Find out how to suggest improvements to publication at
http://www.data.gov/issue/?media_url=http://catalog.data.gov/dataset/goniophotometer-for-specular-gloss-calibrations-glossmeter Do you think this data is incorrect? Let us know